Monarch Anti-Corrosion Systems
Please select a product to view the details.
System/Series:
10 - A carbon based coating for HF
|
Type: |
Filled reinforced coatings |
|
Description: |
A carbon flake filled coating for use in
hydrofluoric acid environments. |
|
Application method: |
Spray or brush |
|
Approximate thickness: |
250 or 500 microns |
|
Designation: |
Coating |
|
Suitable substrate: |
Steel, concrete or other Monarch systems
|
|
Temperature limits |
Immersion: |
Ambient 98°C |
|
Fumes spillage : |
90°C |
System/Series:
20 - A mica reinforced coating
|
Type: |
filled reinforced coatings |
|
Description: |
A mica flake reinforced corrosion resistant resin
system for severe environment coating duty or light duty immersion
conditions. |
|
Application method: |
Spray or brush |
|
Approximate thickness: |
1mm |
|
Designation: |
Coating or lining |
|
Suitable substrate: |
Steel |
|
Temperature limits |
Immersion: |
60°C |
|
Fumes spillage : |
90°C |
System/Series:
30 - Light duty glass flake coating
|
Type: |
Glass flake reinforced linings and coatings
|
|
Description: |
A heavy duty coating system formulated from inert
gas flakes and corrosion resistant resins, suitable for use in most
severe marine and industrial applications. |
|
Application method: |
Spray or brush |
|
Approximate thickness: |
1/2 mm |
|
Designation: |
Coating |
|
Suitable substrate: |
Steel |
|
Temperature limits |
Immersion: |
Ambient 38°C |
|
Fumes spillage : |
120°C |
System/Series:
40 - Medium duty glass flake coating
|
Type: |
Glass flake reinforced linings and coatings
|
|
Description: |
A light duty lining system based on corrosion
resistant resins, suitable for immersion service in tanks, vessels
and process equipment. |
|
Application method: |
Spray or brush |
|
Approximate thickness: |
1mm |
|
Designation: |
Coating or lining |
|
Suitable substrate: |
Steel |
|
Temperature limits |
Immersion: |
70°C |
|
Fumes spillage : |
150°C |
System/Series:
Flexicoat - Flexible glass flake coating
|
Type: |
Glass flake reinforced linings and coatings
|
|
Description: |
A flexible vinyl ester system for coating concrete
bund areas against chemical attack due to spillage or occasional
immersion in chemicals. |
|
Application method: |
Spray |
|
Approximate thickness: |
1mm |
|
Designation: |
Coating |
|
Suitable substrate: |
Concrete and steel |
|
Temperature limits |
Immersion: |
Ambient |
|
Fumes spillage : |
Ambient |
System/Series:
Polyflake - Hybrid glass flake coating
|
Type: |
Glass flake reinforced linings and
coatings |
|
Description: |
A light duty lining system based on
polyester/acrylic or vinyl ester/acrylic copolymers and reinforced
with glass flakes. Similar to the 40 series but of lower chemical
resistance. |
|
Application method: |
Spray or brush |
|
Approximate thickness: |
1mm |
|
Designation: |
Coating or lining |
|
Suitable substrate: |
Steel |
|
Temperature limits |
Immersion: |
70°C |
|
Fumes spillage : |
150°C |
System/Series: O.S
Sprey - Single coat glass flake coating
|
Type: |
Glass flake reinforced linings and
coatings |
|
Description: |
A heavy duty coating system formulated from
polyester resins and reinforced with glass flakes. This coating can
be applied in a single coat to 1mm DFT, saving application costs and
time. |
|
Application method: |
Spray |
|
Approximate thickness: |
1mm |
|
Designation: |
Coating |
|
Suitable substrate: |
Steel |
|
Temperature limits |
Immersion: |
70°C |
|
Fumes spillage : |
70°C |
System/Series: 50
- Heavy duty glass flake lining
|
Type: |
Glass flake reinforced linings and
coatings |
|
Description: |
A heavy duty lining system formulated from "C" glass
flakes and chemically resistant resins. Suitable for severe
immersion conditions, having maximum chemical, corrosion and
abrasion resistance. |
|
Application method: |
Spray or trowel |
|
Approximate thickness: |
2mm |
|
Designation: |
Lining |
|
Suitable substrate: |
Steel |
|
Temperature limits |
Immersion: |
100°C |
|
Fumes spillage : |
170°C |
System/Series:
Enviroflake - Styrene free glass flake coating
|
Type: |
Glass flake reinforced linings and
coatings |
|
Description: |
A series of styrene free polyester coatings and
lining systems utilising glass flake reinforcement. Available in 30,
40 or 50 series types. Refer to the appropriate systems above for
more information. |
|
Application method: |
|
|
Approximate thickness: |
|
|
Designation: |
|
|
Suitable substrate: |
|
|
Temperature limits |
Immersion: |
|
|
Fumes spillage : |
|
System/Series:
Filtering - For lining pool filters
|
Type: |
Glass flake reinforced linings and
coatings |
|
Description: |
A special glass flake reinforced lining system
specifically formulated for lining swimming pool filters (ozone and
chlorine) and other industrial vessels. |
|
Application method: |
Spray or brush |
|
Approximate thickness: |
1mm |
|
Designation: |
Lining |
|
Suitable substrate: |
Steel |
|
Temperature limits |
Immersion: |
70°C |
|
Fumes spillage : |
70°C |
System/Series:
Tankering - For lining road/rail tanks
|
Type: |
Glass flake reinforced linings and
coatings |
|
Description: |
A specially formulated glass flake reinforced lining
for the protection of road tankers or rail tankers carrying
aggresive chemicals and industrial waste products. |
|
Application method: |
Spray or trowel |
|
Approximate thickness: |
2mm |
|
Designation: |
Lining |
|
Suitable substrate: |
Steel |
|
Temperature limits |
Immersion: |
100°C |
|
Fumes spillage : |
|
System/Series:
Permaflake - Ultra low permeability
|
Type: |
Glass flake reinforced linings and
coatings |
|
Description: |
The ultimate glass flake system with the lowest
permeability offering the longest life. The best system for critical
applications. |
|
Application method: |
Spray or trowel |
|
Approximate thickness: |
1mm spray, 2mm trowel |
|
Designation: |
Coating or lining |
|
Suitable substrate: |
Steel |
|
Temperature limits |
Immersion: |
100°C |
|
Fumes spillage : |
170°C |
System/Series: 60
- Glass mat reinforced lining
|
Type: |
Concrete protection reinforced linings |
|
Description: |
A heavy duty multi-layer lining system for special
applications employing a silica filled base coat, two layers of
C.S.M fibreglass reinforcement and "C" glass surface
tissue. |
|
Application method: |
Trowel and hand lay up |
|
Approximate thickness: |
3-4mm |
|
Designation: |
Lining |
|
Suitable substrate: |
Steel or concrete |
|
Temperature limits |
Immersion: |
60°C - 70°C |
|
Fumes spillage : |
|
System/Series:
70 - Filled flooring and concrete tank lining
|
Type: |
Concrete protection reinforced linings |
|
Description: |
A silica filled glass cloth reinforced resin based
concrete protection system. Suitable for immersion service in tanks
and trenches as well as flooring. Specify /CS for
service. |
|
Application method: |
Trowel |
|
Approximate thickness: |
3-4mm |
|
Designation: |
Flooring or lining |
|
Suitable substrate: |
Concrete |
|
Temperature limits |
Immersion: |
75°C |
|
Fumes spillage : |
150°C |
System/Series:
Elastoshield - Polyurea coating/lining
|
Type: |
Concrete protection reinforced linings |
|
Description: |
A polyurea elastomer applied by plural component
spray equipment. Hardens in 3 seconds. For lining secondary
containment bunds and many other applications. |
|
Application method: |
Plural spray |
|
Approximate thickness: |
1mm+ |
|
Designation: |
Coating or lining |
|
Suitable substrate: |
Concrete, geotextile, steel |
|
Temperature limits |
Immersion: |
Ambient |
|
Fumes spillage : |
Ambient |
|